Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Table of Contents
maxLevel2
minLevel2

...

Also, the property auth_token_key should be set up in the poller configuration.


Another potential cause of a 401 error is the  linux system clock on the Poller being too far out of sync with the Primary. in this case, you may see an error similar to below, where the auth.log is saying the token has expired. Ensuring the clocks are in sync will resolve this issue.

Image Added

Configuring a poller over https

...

Premature Connection Close

The web server closed the connection before the user agent could receive the whole response or that the user agent got destroyed, which forces all connections to be closed immediately.

We can tune the following values to prevent this error to happen: 

In the primary server

If the poller is taking too long to respond, we can increase the value of omkd_inactivity_timeout in <omk_dir>/conf/opCommon.json.

...