Event | Type | Stateful | Cancelling Event | AddedDescription | |
Alert "Custom Alert Name" *** | Fault | Yes | Alert "Custom Alert Name" ClosedNMIS 8.3.18GClosed | This is the catch all for custom alerts. More details about Custom Alerts for SNMP MIB Polling can be found at Alerts - Using models to generate custom events | |
Alert: BGP Peer Down | Fault | Yes | Alert: BGP Peer Down Closed | A BGP Routing Protocol Peer has been detected to be down. | |
Alert: GE Alarm Active | Fault | Yes | Alert: GE Alarm Active Closed | A GE Alarm is active on the node. | |
Alert: High Disk Usage | Fault | Yes | Alert: High Disk Usage Closed | The node has high disk usage (disk is getting full) | |
Alert: High Memory Usage | Fault | Yes | Alert: High Memory Usage Closed | The node has high memory utilisation. | |
Alert: High Number of System Processes | Fault | Yes | Alert: High Number of System Processes Closed | A high number of system processes has been detected on the node. | |
Alert: High Oper Completion Time | Fault | Yes | Alert: High Oper Completion Time Closed | The Cisco IPSLA operation has high completion time. | |
Alert: High Swap Usage | Fault | Yes | Alert: High Swap Usage Closed | The node has high SWAP Memory utilisation. | |
Alert: High TCP Connection Count | Fault | Yes | Alert: High TCP Connection Count Closed | The node has a high number of TCP connections. | |
Alert: RTT Completion Status Not OK | Fault | Yes | Alert: RTT Completion Status Not OK Closed | The Cisco IPSLA operation has not completed correctly. | |
Alert: Virtual Machine not Powered On | Fault | Yes | Alert: Virtual Machine not Powered On Closed | The Virtual Machine is NOT powered on, this may or may not be a desirable state. | |
Interface Down | Fault | Yes | Interface Up | NMIS 8.1.1An interface NMIS is managing has gone down (physical or logical outage). | |
NMIS runtime exceeded | Admin | No | N/A | Indicating that the NMIS polling cycle is going too long. | |
Node Down | Fault | Yes | Node Up | NMIS 8.1.1A node is down, stopped responding to ICMP or SNMP packets for longer than the timeout. | |
Node Failover | Fault | No | N/A | NMIS 8.1.1A redundant node pair has failed over, typically a Cisco PIX or ASA. | |
Node Reset | Fault | No | N/A | NMIS 8.1.1A node reset has been detected, the operating system has restarted. | |
Node Configuration Change | Config | No | N/A | NMIS 8.3.18GA configuration change has been detected on this node. | |
Proactive Calls Utilisation | Threshold | Yes | Proactive Calls Utilisation Closed | NMIS 8.1.1There are too many calls, and you need more lines. | |
Proactive CPU | Threshold | Yes | Proactive CPU Closed | NMIS 8.1.1The configured CPU threshold of the node has been exceeded. | |
Proactive CPU User | Threshold | Yes | Proactive CPU User Closed | NMIS 8.3.24GThe User CPU utilisation threshold has been exceeded. | |
Proactive CPU System | Threshold | Yes | Proactive CPU System Closed | NMIS 8.3.24GThe System CPU utilisation threshold has been exceeded. | |
Proactive CPU IO Wait | Threshold | Yes | Proactive CPU IO Wait Closed | NMIS 8.3.24GThe IO (Input/Output) Waiting for CPU threshold has been exceeded. | |
Proactive CPU Idle | Threshold | Yes | Proactive CPU Idle Closed | The Idle CPU utilisation has fallen below the configured threshold. | |
Proactive Dead Modem | Threshold | Yes | Proactive Dead Modem Closed | NMIS 8.1.1A modem is dead and probably should be put out to pasture. | |
Proactive Interface Availability | Threshold | Yes | Proactive Interface Availability Closed | NMIS 8.1.1The configured interface availability threshold of the node has been exceeded. | |
Proactive Interface Discards Input Packets | Threshold | Yes | Proactive Interface Discards Input Packets Closed | NMIS 8.1.1The configured threshold for INPUT packets being discarded by the interface. | |
Proactive Interface Discards Output Packets | Threshold | Yes | Proactive Interface Discards Output Packets Closed | NMIS 8.1.1The configured threshold for OUTPUT packets being discarded by the interface. | |
Proactive Interface Error Input Packets | Threshold | Yes | Proactive Interface Error Input Packets Closed | NMIS 8.1.1The configured threshold has been exceeded for INPUT packets with errors being received by the interface. | |
Proactive Interface Error Output Packets | Threshold | Yes | Proactive Interface Error Output Packets Closed | NMIS 8.1.1The configured threshold has been exceeded for OUTPUT packets with errors being sent by the interface. | |
Proactive Interface Input NonUnicastUtilisation | Threshold | Yes | Proactive Interface Input NonUnicast Closed | NMIS 8.1.1Utilisation Closed | The configured interface INPUT utilisation threshold of the node has been exceeded. |
Proactive Interface LOW Input Utilisation | Threshold | Yes | Proactive Interface LOW Input Utilisation Closed | NMIS 8.1.1The interface has very LOW INPUT utilisation. | |
Proactive Interface Output NonUnicastUtilisation | Threshold | Yes | Proactive Interface Output NonUnicast Closed | NMIS 8.1.1Utilisation Closed | The configured interface OUTPUT utilisation threshold of the node has been exceeded. |
Proactive Interface LOW Output Utilisation | Threshold | Yes | Proactive Interface LOW Output Utilisation Closed | NMIS 8.1.1The interface has very LOW OUTPUT utilisation. | |
Proactive Memory Free | Threshold | Yes | Proactive Memory Free Closed | NMIS 8.1.1Closed | The available free memory is below the configured threshold. |
Proactive Memory Utilisation | Threshold | Yes | Proactive Memory Utilisation Closed | The memory utilisation has exceeded the configured threshold. | |
Proactive Heap Utilisation | Threshold | Yes | Proactive Heap Utilisation Closed | The heap utilisation has exceeded the configured threshold. | |
Proactive Modem Utilisation | Threshold | Yes | Proactive Modem Utilisation Closed | NMIS 8.1.1The modems are being overused, and should probably be retired now. | |
Proactive Reachability | Threshold | Yes | Proactive Reachability Closed | NMIS 8.1.1The overall reachability of the node has has fallen below the threshold. | |
Proactive Response Time | Threshold | Yes | Proactive Response Time Closed | NMIS 8.1.1The response time threshold of the node has been exceeded. | |
Proactive Temp | Threshold | Yes | Proactive Temp Closed | NMIS 8.1.1The configured threshold for temperature of the node has been exceeded. | |
RPS Fail | Fault | No | N/A | NMIS 8.1.1The redundant power supply has failed. | |
SNMP Down | Fault | Yes | SNMP Up | NMIS 8.1.1 |
...
SNMP communication to the node has a problem. | ||||
Service Down | Fault | Yes | Service Up | A service NMIS is managing has failed to respond. |