Status | ||||||
---|---|---|---|---|---|---|
|
Important
- import_nodes.pl now assumes less default values, you may need to add new columns to your import csv like threshold and roleType, the script will output which values are missing that must be defined
...
- Group summary node down count for nodes that were unreachable for a long time has been corrected and will now be properly counted down and be included in the total count of the group
- Services using NMAP now use --host-timeout argument instead of --host_timeout
- Model fix: cpu-cpm to cpu_cpm
- OID's in models should not start with ".", they are now automatically stripped out when a model is loaded
- issues creating support zips
- installer makes sure CPU has avx so that it can run Mongo
- Node editor no longer limits characters allowed in community strings
- some net-snmp versions do not support all hrSWRun* oids, error not finding value would cause snmp down "error-status at error-index 0", this will no longer cause snmp down and collection will continue
- ss-cpu graph showing older data with no ssCpuRawSteal data will now render properly
- nmis-cli act=delete-schedule id=ALL fixed
- Nodes with model setting of '' could cause errors in some cases, this is resolved (and model value will be changed to automatic on node save if model is empty)
- Fixes GUI not loading when cluster_id's not matching (previously NMIS would not allow object to be created, now it prevents it from saving)
NMIS 9.5.0
Status | ||||||
---|---|---|---|---|---|---|
|
...
- Updated services check for web availability in the installer
- Improve installer with timestamps, indented urls, don't install unneeded packages
- Ensure traceroute and mtr are installed by NMIS installer
- Remove end-of-life Debian 8 (Jessie) code
- Keep Inventory configuration/group in sync on update
- Add new action
nmis-cli act=inventoryrefresh
to refresh inventory
NMIS 9.4.5
...
- NMIS 9 configuration can be now set up using the Primary node.
- Fixed bug when renaming a node on a specific situation, when the node had track of files that doesn't exist anymore. The message was "Failed to relocate inventory storage XXX: file "/nodes/namenode/interface/inloopback0.rrd" does not exist, cannot relocate!".
- Fixed bug in the NMIS interface that, in some situations, shows the wrong color (green) for unreachable nodes. It happened when the node was unreachable but a node down event does not exist.
Fixed cgi-bin/models to handle distinction between config nmis_default_models and nmis_models directories for listing, and to use nmisng::util::getmodelfile to read the appropriate model file (custom or default); any written out data already went to the custom model directory.
- Replace legacy logging code.
- Fixed "Network Tools >> SNMP Tool" that was opening when the node was not active.
NMIS 9.0.5
Status | ||||||
---|---|---|---|---|---|---|
|
...
- Smarter non-interactive installation with Preseeding
- Support to See poller nodes from the primary server.
- Fixed visualisation problem with numeric node nodes. Nodes with only numbers on the name, like "12345" were causing problems on the system.
- Show poller_event_log by default if the NMIS9 is a Primary, in case syslog is configured to get network events on Primary.
- mojolicious 8.x is a new dependency that has a totally rotten default format for mojo::log. Fixed log format and set log_level to info which is no longer the default.
- Fixed race condition in the poll process causing the catchall inventory data not being updating properly when the ping operation runs at the same time.
- Fixed fpingd process on debian 10 was causing heaps of space padding to be added if $0 is changed.
- Fixed NMIS9 runtime graph was not working.
- Change sysLocation field title to 'SNMP Location' to declash with manually configured location field, which is titled 'Location'.
- Added hr* sections to net-snmp model so opCharts can know what charts to make.
- Fixed network_summary_group view had empty columns.
- Fixed node response time graphs for nodes (shown NaN on previous):
...
- nmisng nodes now handle cluster_id on get_events_node: This is going to allow opHA to remove events from the poller on a peer deletion, so no data from the poller should remain. Also fix node_admin when dumping a node from the poller (Now will be able to get also event_data).
- Show message on delete node errors.
- Minor fixes ported from NMIS8:
- Added support for fping inter packet gap for some firewalls. New configuration options added: fastping_interval and fastping_target_interval.
- IPrevent NMIS from failing when an escalation event element is c:\\
- Adding the new opConfig "Node Configuration Change Detected event"
- Fixed newlines being included in WMI error messages
- Calling /proc/cpuinfo in the Support ZIP
- run-reports.pl makes sure the reports directory exists
- Optimisation to stop running services if no service polling required on a node
- work around net-snmp snmpd which reports almost anything as hrfixeddisk
- fixes for the Cisco Temperature model
- loadServiceStatus: A new parameter is added that allows filter by all clusters. This will allow opCharts to show Monitored Services from the poller.
- services.nmis: Added Opmantek.pl
- nmis-cli: On job type collect wasn't filter by local nodes.
- purge_op_status: Changed to 7 days by default.
- Display node name in opstatus.pl
NMIS 9.0.2