Overview
Server Specifications
Small | Medium | Large | Massive | |
---|---|---|---|---|
OS Storage | 20GB | 20GB | 20GB | 20GB |
Data Storage | 40GB | 60GB | 140GB | 280GB |
Memory | 2GB | 4-8GB | 8GB | 16GB+ |
CPU | 2 x vCPU | 2 to 4 x vCPU | 4 to 6 x vCPU | 8+ vCPU |
Device Count | < 500 devices | < 1500 devices | < 2500 devices | A very large |
Element Count | 2000 elements | 8000 elements | 14000 elements | A very large number of elements |
Elements are additional data being collected, an interface is an element, a CBQoS class is an element.
An element requires additional SNMP polling to collect the values and then storage on the disk to save the data.
Baseline Performance
Once you know device counts and have an idea of the virtual server (yes you can use physical servers) specifications, it is a good idea to get an idea of baseline performance.
The baseline is to establish how NMIS and the virtual server are performing, add ~50 nodes and see how it is performing. We have a customer polling ~200 nodes and the average poll cycle is about 20 seconds. So if you are able to poll 50 nodes in less than 20 seconds your performance should be OK, if it is longer than this, then you might need to look at CPU and Disk performance. This will also give you an idea of memory footprint.
Adding Nodes to NMIS
If you want to stop the polling and then run an update cycle, then a collect cycle manually, then start the polling.
To stop polling modify the configuration option global_collect to false or stopping polling in the crontab, comment out this line:
#*/5 * * * * /usr/local/nmis8/bin/nmis.pl type=collect mthread=true maxthreads=8
Then add nodes, all of them at once or in batches. Restart fpingd so that it reloads all the nodes you added.
/usr/local/nmis8/bin/fpingd.pl restart=true
Then run an update manually with nohup, if you have 12GB of memory you can give it lots of threads, probably 20 should do it, but watch your memory usage you can probably get to 30 threads.
cd ~ nohup /usr/local/nmis8/bin/nmis.pl type=update mthread=true maxthreads=20&
This will take a while to run the first time, when it finishes, run a collect cycle the same way
nohup /usr/local/nmis8/bin/nmis.pl type=collect mthread=true maxthreads=20&
Now all the big disk activity is done and you should be able to start NMIS polling by letting the poller go again.
*/5 * * * * /usr/local/nmis8/bin/nmis.pl type=collect mthread=true maxthreads=<MAX THREADS BASED ON YOU BASELINE>
Configuration Considerations
*/2 * * * * /usr/local/nmis8/bin/nmis.pl type=summary 4-59/5 * * * * /usr/local/nmis8/bin/nmis.pl type=threshold
In Config.nmis:
'threshold_poll_cycle' => 'false', 'nmis_summary_poll_cycle' => 'false',
The other BIG consideration is what is your polling policy, the more interfaces you collect on, the more disk, cpu and memory you will consume, just collecting more data may not help you operationally, collect the right data, which is how NMIS has been configured.
If you hare having problems scaling your NMIS installation, you could contact Opmantek for assistance.