The new version will need to be downloaded and this tutorial assumes you have put it in ~/tmp, it can be anywhere you like but you will have to adjust the command to untar. 

Upgrade Steps

...

Code Block
scp opExport-New-Version.tar.gz user@server:/tmp/

Upgrade Steps

Code Block
cd /usr/local/omk
  1. Backup old configuration installation 

    Code Block
    mkdir conf_date_here
    cp -r conf/* conf_date_hereomk omk-backup-<date>/ 
  2. Stop the current service 

    Code Block

    service (note, if your server is running multiple omkd then you will need to use ps -ef to find the correct one).  The opmante.exe WITHOUT the webserver is the one we want.

    Code Block
    #more than one omkd use these instructions, note: do not use service omkd stop if you have #more ifthan thatone doesopmantek.exe
    not workps try-ef kill| `cat /tmp/prefork.pid`
    
    # verify it omkd is stopped
    ps aux | grep opman
    
    # if they are still running kill them
    killall opmantek.exe      grep opmantek.exe
    [root@server ~]# ps -ef | grep opmantek.exe
     root 944 742 0 20:44 pts/0 00:00:00 grep opmantek.exe
     root 16533 1 8 Dec12 ? 09:44:54 opmantek.exe
     root 20229 1 0 Dec06 ? 00:02:10 opmantek.exe webserver 
    
    kill 16533 # (leave 20229, it is not opExport)
    
    ps aux | grep opmantek.exe  
  3. Untar the new version 

    Code Block
    cd /usr/local
    tar -zxvf ~/tmp/opExport-New-Version.tar.gz 
  4. Upgrade the configuration 

    Code Block
    cd /usr/local/omk
    cp ./bin/opupdateconfig.pl ./install/opCommon.nmis ./conf/
    cp install/users.dat conf/ opCommon.nmis
     cd conf  

    *if you are upgrading the MySQL server daemon, you will need new schemas: 

    Code Block
    cp install/*.json conf/
  5. Clean up old files (very important if server has fallen behind)

    Code Block
    rm /usr/local/omk/log/*
    rm -rf /usr/local/omk/var/perf/*
  6. Start the service back up 

    Code Block
    service omkd start
  7. Load the upgraded GUI in a web browser http://your.upgraded.server.name.or.ip:3000/omk/opExport, this is required to  accept the EULA, if this is not done schemas will not be saved in the next step!

    Image Removed

    Push schema to NMIS server from MySQL (only if the upgraded server is NMIS server) .Image Added
  8. Load the MySQL Server GUI in web browser http://your.MySQL.Server:3000/omk/opExport, push the schema to the upgraded server